Spark detector FSK-1/ FSK-2
The FSK-1 (FSK-2) spark detector is an opto-electronic monitoring system and has been developed to detect sparks in the near infrared range. The spark detector is suitable for installation in closed piping systems where no outside light can enter the pipe. The spark detector can be installed easily in pipes of different nominal dia/meters (100 - 2000 mm) without any modification of the existing suction system thanks to its special housing. Inspection flaps for maintenance work are not required. Installation diameter is 40 mmand is quickly cut with a special hole-cutter. Maximum ambient temperature should not exceed 60° C. The spark detector is designed to protection class IP 65.
|
| (please click for fullscrean) |
|
|
 |
|
Spark detector FSL-1/ FSL-2
Spark detector with optical fibre for temperatures up to 300° C. .
Spark detector FST-1/ FST-2
Housing as spark detector FSK-1 (FSK-2), but with the following modifications: daylight insensitive thermal spark detector for detecting sparks and heat radiation above 300°C with built-in daylight filter. Suitable for installion in open systems subject to extraneous light, but without direct exposure to sunlight. Maximum ambient temperature of the electronic components 60°C. |
| (please click for fullscrean) |
|
|
 |
|
Spark detector FSK-1-S/FSK-2-S
Electronics as spark detector FSK-1 (FSK-2), but with the following modifications: acid-resistant plastic housing, completely sulphuric acid proof. The spark detector is suitable for installation on production lines in the battery and chemical industries. Detection range up to approx. 25 metres.
|
| (please click for fullscrean) |
|
|
 |
|
By-Pass
smoke detector
BRM 1
By-pass smoke detectors are installed in exhaust air ducts and on the cleaned gas side of filter housings in order to prevent filter fires. Air is extracted continually from the system being monitored by a series of pipes, and fed to an optical smoke detector. In the event of an alarm, the filter system can be switched off or an extinguishing device activated.
|
| (please click for fullscrean) |
|
|
 |
|
Thermal detector THM 1
Overheating of material, which could lead to a fire, or temperature in creases during the production process, are monitored by thermal detectors. In the event of an alarm, the filter system can be switched off or an extinguishing device activated.
|
| (please click for fullscrean) |
|
Accessories |
 |
|
Connection box KK 1 for BM 2/BM 3
The connection box is designed for the plug-in connection of 1 to 6 spark detectors, and facilitates installation and maintenance. The spark detectors are connected to the internal circuit board via their standard plugs. It is only necessary to connect the cable from the spark alarm unit. The connection box is supplied complete with all cable screw connections. The protection class conforms to IP 66. |
(please click for fullscrean) |
|
|
 |
|
Connection box 2 for BM 4 and BM 5
For the plug-in connection of FSK 2 spark detectors to the BM 4 and BM 5 spark alarm unit. Otherwise as KK 1, with protection class IP 65. For max.2 spark detectors per connection box. |
(please click for fullscrean) |
|
|
 |
|
Connection box KK 1 and KK 2 (ATEX)
For the plug-in connection of FSK-1 ATEX (KK 1 ATEX) and
FSK-2 ATEX (KK 2 ATEX). For max. 2 spark detectors per connection box.
The protection class conforms to IP 66.
|
(please click for fullscrean) |
|
|